5.2 Amenities such as mail boxes and storage facilities shall be properly Maintained.
Basements, Cellars, and Crawlspaces
5.3 Use of a Crawl Space as a Habitable Room is prohibited.
5.4 Any Basement or Cellar used as a Dwelling Unit shall have the following requirements:
5.4.1 window area for light and ventilation shall be at least 50% above ground. Window wells are permitted if kept free of ice, snow, debris and litter;
5.4.2 floors and walls shall be impervious to water leakage;
5.4.3 Service rooms shall be separated from the remainder of the Dwelling Unit by a suitable fire separation; and
5.4.4 access to each Habitable Room shall be gained without passage through a service room.
Compost Heaps
5.5 The Occupant of a Residential Property may provide for a compost heap or bin in accordance with the health regulations, provided that the compost pile is no larger than one square metre (10 sq. ft.) and 1.8 metres (6 ft.) in height and is enclosed on all sides by concrete block, or lumber, or in a metal frame building with a concrete floor, or in a commercial plastic enclosed container designed for composting.
5.6 Compost heaps or bins shall not be placed in the front Yard or exterior side Yards.
5.7 Compost heaps or bins shall be constructed to prevent the entry of rodents or other animals, be provided with a tight fitting cover which shall be kept closed at all times except when material is being placed therein, and be maintained in a clean and sanitary condition.
Disconnected Utilities
5.8 No Owner of residential buildings or any Person or Persons acting on behalf of such Owner shall disconnect or cause to be disconnected any service or utility supplying heat, electricity, gas, refrigeration or water to a dwelling unit occupied by a tenant or lessee, except for such reasonable period of time as may be necessary for the purpose of Repairing, replacing or otherwise altering said service or utility.
Doors, Windows, and Skylights
5.9 Windows, skylights, doors and basement or Cellar hatchways shall be Maintained in good Repair, weather tight and reasonably draft-free. Maintenance includes painting, replacing damaged doors, door frames and their components, window frames, sashes and casing, replacing non-serviceable hardware, weather-stripping and re-glazing.
5.10 In a Dwelling Unit all windows and skylights intended to be opened and all exterior doors shall have hardware so as to be capable of being locked or otherwise secured from inside the Dwelling Unit without the use of keys or tools.
5.11 Where storm windows and doors are installed in a dwelling that shall be Maintained in good Repair.
5.12 All shutters on windows shall be Maintained in good Repair, including painting, replacing or other suitable means to prevent deterioration due to weather and insects.
5.13 All windows and skylights intended to be opened shall be readily operable under normally applied pressure without jamming or binding so as to perform their intended function.
5.14 All windows and skylights in a Dwelling Unit that are capable of being opened shall be fitted and equipped with screens that are Maintained in good Repair and free from defects and missing components.
5.15 Where an opening is used for illumination or ventilation and is not permanently protected by a window, skylight or door so as to exclude rodents, vermin and insects it shall be adequately screened with wire mesh or other durable material; otherwise protected so as to effectively prevent the entry of rodents, vermin and insects.
5.16 At least one entrance door in every Dwelling Unit shall have hardware so as to be capable of being locked from both inside and outside the Dwelling Unit.
5.17 Solid Core, hollow metal, or insulated steel doors shall be installed and Maintained for the entrances of Dwelling Units and hallways.
Egress
5.18 Every Dwelling and each Dwelling Unit within it shall have a continuous and unobstructed passage from the interior of the Dwelling Unit and the Dwelling to the outside of the Dwelling at street or grade level.
5.19 When an exterior staircase is used as a second means of egress, it shall be continued to ground level.
5.20 When a second means of egress requires a person or persons to travel across a roof top to reach a fire escape or a second stairwell, then a walkway complete with railing must be installed and Maintained across said roof tops.
Electrical Service
5.21 Every dwelling unit shall be wired for and provided with electricity.
5.22 Elevators intended for use by tenants shall be properly Maintained and kept in operation.
5.23 In apartment buildings where a voice communication system exists and or where a security locking and release system for the entrance is provided and is controlled from each dwelling unit such systems shall be maintained in good repair.
5.24 Every habitable room in a dwelling shall have at least one electrical duplex outlet for each 11.15 square metres (120 square feet ) of floor space, for each additional 10 square metres (100 square feet) of floor space a second duplex outlet shall be provided.
5.25 Every kitchen shall have at least two electrical duplex outlets which shall be on separate circuits.
5.26 All electrical services shall conform to and be Maintained to the regulations set by statute.
Emergency Contacts and Apartment Identification
5.27 Every Owner shall provide, install, and maintain contact information in a common area in case of an emergency on a 24 hour basis where an authorized person responsible for the Property can be reached.
5.27.1 In buildings having more than one Dwelling Unit, each Dwelling Unit door connected to interior common space, hallways, exits, etc. shall have the unit number posted on or beside the door and be installed in a manner and size that can be easily seen by visitors, service persons and emergency response personnel.
Garbage Disposal
5.28 Every Dwelling and every Dwelling Unit within the Dwelling shall have such receptacles as may be necessary to contain all garbage and rubbish.
5.29 Receptacles shall be:
5.29.1 constructed of a watertight material;
5.29.2 constructed to prevent the entry of rodents;
5.29.3 provided with a tight fitting cover, which shall be kept closed at all times except when garbage is being placed therein;
5.29.4 maintained in a clean and sanitary condition; and
5.29.5 located in the rear Yard of the building but shall not be placed within 3.05 metres (10') vertically or horizontally of any opening in the structure.
5.30 Multiple Dwellings that do not have interior garbage rooms shall have Maintained and installed a receptacle large enough to contain all garbage and rubbish.
5.31 In no event shall garbage and/or garbage receptacles or recycle boxes be placed in the front yard or porch of any residential dwellings other than for immediate pick-up.
5.32 Tenants shall have daily access to garbage receptacles and garbage rooms.
5.33 Garbage and rubbish shall be stored in receptacles and removed as required by bylaw.
5.34 Receptacles shall be acceptable plastic bags or containers made of watertight construction provided with a tight fitting cover and Maintained in a clean state.
5.35 Where Repairs or cleanup require the use of bins, these bins shall be emptied when materials or debris reach the top of the bin or when odours are offensive and may be a health hazard.
5.36 The lids to the bins shall be closed when the bins are not in use.
5.37 Accumulation or storage of garbage or refuse in public halls or stairways shall be prohibited, at all times.
General Cleanliness
5.38 Every Occupant of a Residential Property shall Maintain the Property or part thereof and the land which they occupy or control, in a clean, sanitary and safe condition and shall dispose of garbage and debris on a regular basis in accordance with municipal bylaws.
5.39 Every Occupant of a Residential Property shall Maintain every floor, wall, ceiling and fixture, under their control, including hallways, entrances, laundry rooms, utility rooms and other common areas, in a clean, sanitary and safe condition.
5.40 Accumulations or storage of garbage, refuse, appliances, or furniture in a means of egress shall not be permitted.
Heating and Heating System
5.41 Every Dwelling Unit shall be provided with a heating system capable of Maintaining a minimum temperature of 21.1C (70F).
5.42 All common areas or internal entranceways shall be provided with heating systems capable of Maintaining a minimum temperature of not less than 18 degrees C (65 degrees F).
5.43 Room temperature shall be determined at any point in the room.
5.44 Every building or part of a building which is rented or leased as Dwelling or living accommodation and which, as between the tenant or lessee and the landlord, is normally heated by or at the expense of the landlord shall, between the 15th day of September in each year and the 1st day of June of the following year, be provided with adequate and suitable heat by or at the expense of the landlord; and for the purposes of this bylaw, "adequate and suitable heat" means that the minimum temperature of the air in the accommodation which is available to the tenant or lessee is 21.1C (70F).
5.45 No residential unit shall be equipped with portable heating equipment as the primary source of heat.
5.46 Only heating equipment approved for use by a recognized standards testing authority shall be provided.
5.47 The heating system shall be Maintained in good working condition so as to be capable of heating the Dwelling safely to the standard required by this Bylaw.
5.48 All exposed pipes in habitable rooms shall be kept sufficiently protected so as to prevent a safety hazard.
Kitchens
5.49 In every room in which meals can be prepared, or are prepared, there shall be installed and Maintained;
5.49.1 a suitable enclosed cupboard or shelving unit for storing food with not less than 0.226 cubic metres (8 cubic feet) of space;
5.49.2 a space provided for cooking and refrigeration appliances, including suitable electrical or gas connections for the cooking appliances;
5.49.3 work surfaces at least 1.2 metres (4 feet) in length x 60 centimeters (2 feet) in width, exclusive of the sink, that are impervious to moisture and grease and easily cleanable so as not to impart any toxic or deleterious effect to food; and
5.49.4 a sink that,
5.49.4.1 is surrounded by surfaces impervious to grease and water including at least the lower 127mm (5 inches) of the adjacent wall; and
5.49.4.2 is served with hot and cold running water.
Light
5.50 Every Habitable Room except a kitchen shall have a window or windows, skylights, translucent panels or glass area of an outside door that faces directly to outside space and admits as much natural light as would be transmitted through clear glass equal in area to five per cent of the floor area of the room.
5.51 Public halls, common rooms, stairs, exit stairwells, porches and verandas in multiple Dwellings shall be lighted to provide a minimum level of illumination, meaning illumination of at least 50 lux (4.6 foot candle power) at all times of the day and night.
5.52 Full time lighting systems are required except during those hours when daylight suffices adequately to light the public halls.
5.53 Lighting equipment shall be provided installed and Maintained throughout to provide sufficient illumination.
5.54 Every Bathroom, Toilet Room, laundry room, furnace room, Basement, Cellar or non-habitable work room and kitchen shall be provided with a permanent electrical light fixture.
Occupancy Standards
5.55 The number of Occupants residing on a permanent basis in an individual Dwelling Unit shall not exceed the maximum occupant load as prescribed by the Building Code Act, 1992, S.O. 1992, c. 23 as amended.
5.56 No room shall be used for sleeping purposes unless it has a minimum area of at least 7 square metres (75 square feet), where built in cabinets/closets are not provided, and no less than 6 square meters (65 square feet) where built in cabinets/closets are provided and no less than that required by the Ontario Building Code as amended.
Plumbing
5.57 All plumbing, including every drain, water pipe, water closet and other plumbing fixtures in a Dwelling and every connecting line to the Sewerage System shall be Maintained in good working order and free from leaks or defects, and all water pipes and appurtenances thereto shall be protected from freezing.
5.58 All plumbing fixtures shall be connected to the Sewerage System through water seal traps.
5.59 Every Dwelling shall be provided with an adequate supply of potable running water from a source approved by the Medical Officer of Health.
5.60 All Dwellings shall have the sanitary facilities connected to a Sewerage System.
5.61 Every fixture shall be of such materials, construction and design as will ensure that the exposed surface of all parts are hard, smooth, impervious to cold or hot water, readily accessible for cleansing, and free from blemishes or cracks or other interstices that may harbour germs or impede thorough cleansing.
Toilet and Bathroom Facilities
5.62 Every wash basin, bathtub and shower shall have an Adequate supply of hot and cold running water and every water closet shall have an Adequate supply of running water.
5.63 Every Dwelling Unit (except as otherwise provided) shall contain toilet and bathroom plumbing fixtures consisting of at least one water closet, one wash basin and one bathtub or shower.
5.64 Hot water shall be so served that it may be drawn from the tap at a temperature of 43*C (110*F).
5.65 All Bathrooms and Toilet Rooms shall be located within and accessible from within the Dwelling Unit except that the Occupants of two Dwelling Units each containing not more than two Habitable Rooms may share toilet and bathroom facilities provided that access to the said toilet and bathroom facilities can be gained without going through rooms of either or another Dwelling Unit or outside of the building.
5.66 All Bathrooms and Toilet Rooms shall be fully enclosed.
5.67 The wash basin shall be located in the same room as the water closet, or in an immediately adjoining room.
5.68 Every Dwelling shall have at least one sink in addition to a kitchen sink.
5.69 Every Dwelling Unit shall be provided with hot and cold running water.
Ventilation
5.70 Every Habitable Room except living rooms and dining rooms shall have an opening or openings for ventilation providing an unobstructed free-flow area of at least 0.28 square meters (3 square feet) or an approved system of mechanical ventilation such that the air is changed once every hour.
5.71 All enclosed spaces including Basements, Cellars, attics or roof spaces, and Crawl Spaces shall be Adequately vented.
5.72 Where an opening is used for ventilation and is not permanently protected by a window or door so as to exclude rodents, vermin and insects it shall be:
5.72.1 Adequately screened with durable material; and
5.72.2 otherwise protected so as to effectively prevent the entry of rodents, vermin and insects.
5.73 Any openings for natural ventilation shall be protected with insect screen of corrosion-resistant material.
5.74 Every Bathroom or Toilet Room shall have an opening or openings for ventilation providing an unobstructed free-flow area of at least 0.09 square metres (1 square foot), or an equivalent such as an electric fan and a duct which shall terminate outside, shall be provided, installed and Maintained.
5.75 All mechanical ventilation systems shall be maintained in good working order.
Walls, Ceilings and Floors
5.76 Every floor, wall and ceiling in a Dwelling shall be Maintained in a clean, sanitary condition.
5.77 Every floor in a Dwelling shall be acceptably level and be Maintained so as to be free of all loose, warped, protruding, broken or rotted boards, and cracks. "Acceptably level" shall be defined as not more than 75 mm (3 inches) slope in 3 metres (10 feet) and not more than 25mm in 610 mm (1 inch in 2 feet).
5.78 Floors above an unheated space or a non-insulated Basement, Cellar, or Crawl Space shall have existing insulation Maintained.
5.79 Where necessary, interior walls shall have baseboards that shall be Maintained in good Repair and tight fitting so as to prevent the accumulation of dust and garbage.
5.80 All Bathroom walls surrounding bathtubs and showers shall be water proof and floors shall be water resistant.